Company Profile Certificate Partnership Download Contact Us Home
Technology

Coil Options

Normally Closed
Normally Open
MK-series
LCU
MCU
RS SERIES
New Product
Other Control Valves
Other Control Valves  
Manu broad
Page1 Page2 Page3

Page4

PRESSURE SUSTAINING VALVE
  • Pressure sustaining valve is utilezed when installing pipes for users.
    It primaritly matches up with the minimum working pressure inside the tap
    water pipe, balancing up-stream and down-stream pressure during normalcy
    and emergency, and maintains constant pressure inside the pipe.
  • Pressure sustaining valve can sustain the maximum working pressure inside
    the pipe when installed in water supply areas.

 

TOP

SOLENOID CONTROL VALVE
Solenoid control valve is a kind of isolation valve, which can
substitute traditional gate valves, ball valves and butterfly valves,
The gate functioning is easily controlled by electrical power.
The valve can be installed in fire control facility, water supply,
or distaunt location where it's difficult to control the gate opening.
The controller is directly fixed and can be easily installed on piping site.
Interchangeable between manual and solenoid control.

TOP

DIRECT- ACTIVATED PRESSURE REDUCING VALVE
(STALINLESS STEEL 316/ Thread Type )

 

  • Valve Body is made by Stainless Steel #316, suitable for fluid, and Vapor.
  • The gate is designed for opening status, which will not influence the water supply function under unstable inlet pressure condition.
  • When the outlet pressure responds directly to the pressure control chamber and adjusts the setting pressure, it responds quickly and adjusts the pressures accurately.
  • Design of piston and disphragm improves the inability of sustaining pressure and leakage.

 

Applied condition of Direct-activated Pressure Reducing Vales :
  • Installing pressure reducing valve directly in sub-pipe can reduce fluid pressure inside the pipe.
  • Installing a filter in the inlet of pressure reducing valve can prevent block of valve gate casued by
    impurities and limescale.
  • Installing pressure relief valve downstream pressure reducing valve can protect the system.
  • While using screws to connect pressure reducing vlave, joints should be installed in the inlet and
    outlet to make maintainance easy.
Pressure Setting and Flow Rate of Direct-activated Pressure Reducing Vales :
  • Direct-activated pressure reducing valve directly opens and closes the valve gate by the outlet pressure.
    When outlet pressure is under setting pressure, valve gate automatically opens.
    To make valve gate fully open, adjustable pressure range and setting pressure are relative points.
  • A : Pressure drop needed for fully-opened valve gate = B/4 ,B=Adjustable Pressure Range
    Maximum-Minimum
    B: Adjustable Pressure Range ( = Maximun Minimum Adjustable Pressure Rang )
    C: Setting Pressure of Outlet
    P: Pressure of fully-opened outlet valve gate, P=C-A

    Example:
  • Pressure drop needed for fully-opened valve gate for adjusting pressure range 3~9 kgf/cm2 of
    direct-activated pressure reducing valve. A=B/4=9-3/4=1.5 kgf/cm2
    If the setting pressure of outlet is 6 kgf/cm2 , pressure of fully-opened valve gate will be
    P=6-1.5=4.5 kgf/cm2 ( Outlet pressure should go down under 4.5 kgf/cm2 to make valve gate fully open )
 
 

TOP

 

 

KUHNWAY CORPORATION
Add: 2F, No. 84, Sec. 3, Jianguo N.Rd., Taipei 104, Taiwan.
TEL:886-2-25158905~6       FAX:886-2-25096364
E-mail:kuhnway@ms15.hinet.net